Two-phase hybrid stepping motor dynamic voltage 12 to 48V, the current is less than 5A outer diameter of 35 to 86 mm. This drive using the drive's current loop subdivision control, the motor torque ripple is very small, low- Smooth, almost no vibration and noise. High-speed torque is much higher than other two-phase drive, high positioning accuracy. Widely used in the engraving machine, CNC machine tools, packaging machinery and other high resolution requirements on the device.

للطلب والاستفسار
أضغط هنا لمعرفة أقرب وكيل إليك
أو الاتصال بنا مباشرا
الاتصال مفتوح 24 ساعة نحن لا نكل أو نتعب فى سبيل راحتكم
الاتصال من داخل مصر
01221518320
الاتصال من خارج مصر
00201221518320
أو المراسلة على الايميل
mourad3d@hotmail.com
The main Features 
- Average Current Control, TWO-Phase Sinusoidal Output Current Drive 
- ~ 12 is the DC 48V Power Supply, The Internal Integration of 12V and 5V Regulator 
- Optically Isolated Signal INPUT / Output 
- Overvoltage, UNDERVOLTAGE, OVERCURRENT, and Short-Circuit Protection White
- Input voltage DC 12 ~ 48V input 
- the input current of 1 to 5 amps, select the drive a stepper motor. 
- Output current of 0.2A ~ 5A 
- Temperature Operating Temperature -10 to 45 ℃; Storage temperature -40 ℃ to 70 ℃ 
- Humidity not condensing, not drops 
- Gas prohibit combustible gas and fuse dust 
- Weight 200 grams
Control signal interface
- Figure 1 is a wiring schematic of the drive 
- 1, the definition of control signals 
PUL +: step pulse signal is input side or the positive pulse signal input positive terminal 
PUL-: the negative input of the negative input pulse signal Or a positive pulse signal 
DIR +: stepping direction signal input to the positive terminal or negative pulse signal input to the positive terminal 
DIR -: stepping direction signal input of the negative side or reverse step pulse signal input negative terminal 
EN +: offline can reset Signal input side is 
EN-: offline can reset signal input negative terminal 
Offline enable signal is active, reset drive failure to prohibit any pulse, the output of the drive 
component is turned off,at The Motor Holding Torque. 
- Control Signal Connections 
- PC Control Signal CAN BE High, Also CAN BE Low as Effective the When the Active High, at The Control Signal. 
- at The negative Side Together AS A Signal to the Active Low, positive Side of All Control Signals Together AS A signal common. 
- For example, open-collector and PNP output interface circuit diagram is as follows:
Figure 2. Input interface circuit (common cathode connection) 
- Note: the VCC is 5V, R short; 
- VCC value of 12V, R 1K, more than 1 / 8W resistor; 
- VCC value of 24V, R 2K, more than 1 / 8W resistor;
Function Selection (the DIP Switch ON The Drive Panel) 
- the Set The Motor per Revolution Steps 
of The Drive to SET The Number of Steps per Motor Revolution IS 200 is (Whole STEP), 400 (2 Segments), 1600 (. 8 Segments), 3200 Steps ( 16 segments). 
The user can drive the front panel DIP switch SW3 is SW4 bit of the drive to set the number of steps (such as Table 1): 
Table 1 
- Set the output phase current 
- To drive torque stepper motor, the user Can drive panel DIP switch 
- SW1, SW2 is to set the drive output phase current (RMS) unit amperes, the switch position 
- Corresponding to the output current, output current value corresponding different types of drive. Concrete are shown in Table 2. 
- Output Current (A 
Table 2 
Current setting

- the semi-flow function 
- the semi-flow function is a step pulse 200ms, the driver output current is automatically reduced to the rated output current 50%, used to prevent motor heating. 
Fourth, the power interface 
- 1, DC +, DC -: The Connect to Drive Power 
- the DC +:.. the DC Power Level, Power Supply Voltage 48V to the DC 12 is of The maximum of The Current IS. 5A 
. the DC-: the DC Power Supply negative Level 
2, the B-A + AB +: Connect to The two-phase hybrid stepping motor 
drive and two-phase hybrid stepper motor's connection with the four-wire system, the motor windings in parallel and series connection, and connection method, high-speed performance, but the drive current is large (for motor Winding current of 1.73 times),Connected in series when the drive current is equal to the motor winding current. 
Five, the installation 
- Around to have 20mm of space, can not be placed next to the other heating equipment, to avoid dust, oil mist, 
Corrosive gases, Is too big and strong vibration. + 
Figure 3. 
Six fault diagnosis 
1, the status light indicating 
RUN: green light in the normal work. 
ERR: red light, power, light, power indicatorThe status light indicated RUN: green light in the normal work. ERR: red light, power, light, power indicatorThe status light indicated RUN: green light in the normal work. ERR: red light, power, light, power indicator





للطلب والاستفسار
أضغط هنا لمعرفة أقرب وكيل إليك
أو الاتصال بنا مباشرا
الاتصال مفتوح 24 ساعة نحن لا نكل أو نتعب فى سبيل راحتكم
الاتصال من داخل مصر
01221518320
الاتصال من خارج مصر
00201221518320
أو المراسلة على الايميل
mourad3d@hotmail.com

ليست هناك تعليقات:

إرسال تعليق

المشاركات الشائعة